1. If the compressor has been burned or mechanically failed or worn, the refrigerant system will inevitably be polluted. The situation is as follows:
1. The residual refrigeration oil has been carbonized, acidic, and dirty in the pipe.
2. After the compressor is removed, the original system pipe ...
Daily maintenance and upkeep of cold storage refrigeration condensing units include: During the initial operation of the condensing unit, we should always observe the oil level, oil return and cleanliness of the cold room compressor. If the oil is dirty or the oil level drops, we should promptl...
1-Cold storage equipment: Frost on the compressor return air port indicates that the compressor return air temperature is too low. So what will cause the compressor return air temperature to be too low?
It is well known that if the volume and pressure of the same quality of refrigerant are change...
When choosing a cold room refrigeration compressor, the first thing to consider is the refrigeration power you need, as different types of compressors have different operating ranges. If you need low or high power, it is easy to choose from one technology. For medium-power compressors, it is diff...
Fresh-keeping storage is a storage method that inhibits the activity of microorganisms and enzymes and prolongs the shelf life of fruits and vegetables. The preservation temperature range of fruits and vegetables is 0℃~5℃. Fresh-keeping technology is the main method of low-temperature preservati...
1. Why does the compressor have to run continuously for at least 5 minutes and stop for at least 3 minutes after shutting down before restarting?
Stopping for at least 3 minutes after shutting down before restarting is to eliminate the pressure difference between the compressor inlet and exhaust....
1. Internal thermostat (installed inside the compressor)
In order to prevent the air-cooled chiller from running continuously for 24 hours, causing the compressor to run at high load, the electromagnetic switch is bad, the shaft is stuck, etc., or the motor is burned due to the motor temperature....
When you have considered starting a cold storage, have you ever thought about how to manage it after it is built? In fact, it is very simple. After the cold storage is built, how should it be managed correctly so that it can work normally and safely.
1. After the cold storage is built, preparatio...
We are all very familiar with cold storage, which is very common in life. For example, fruits, vegetables, seafood, medicines, etc. all need to ensure freshness. Therefore, the utilization rate of cold storage is getting higher and higher. In order to increase customer satisfaction and higher ben...
Reasons for excessive suction pressure of compressor cold storage equipment
1. The exhaust valve or safety cover is not sealed, there is leakage, causing the suction pressure to rise.
2. Improper adjustment of the system expansion valve (throttling) or the temperature sensor is not close, the suc...
Material preparation before installation
The cold storage equipment materials should be equipped according to the cold storage engineering design and construction material list. The cold storage panels, doors, refrigeration units, refrigeration evaporators, microcomputer temperature control box...
Crankshaft fracture
Most of the fractures occur at the transition between the journal and the crank arm. The reasons are as follows: the transition radius is too small; the radius is not processed during heat treatment, resulting in stress concentration at the junction; the radius is processed ir...